Main Article Content
Quantification of carbon dioxide released from effervescent granules as a predictor of formulation quality using modified Chittick apparatus
Abstract
Purpose: To develop a method for the measurement of carbon dioxide (CO2) released from effervescent formulations.
Methods: Effervescent granules were prepared using sodium bicarbonate and citric acid by fusion and solvent-assisted granulation methods. The amount of CO2 released was determined from the maximum pressure of gas release, time profile of pressure gradient using modified Chittick apparatus and gravimetric changes following effervescence.
Results: The amount of CO2 released from effervescent granules prepared by fusion method was 8.125, 8.763 and 7.98 mM/g measured by ideal gas equation, pressure gradient and gravimetric method, respectively. The formulation prepared by solvent-assisted granulation showed 5.525, 5.475 5.36 mM/g of carbon dioxide measured by the above three methods, respectively. The effervescent granules prepared by fusion method showed approximately 2 % loss in effervescence. However, approximately 39 % loss in effervescence was observed for the formulation prepared by solventassisted granulation. The commercial products showed a loss in effervescence in the range of 5 - 15%.
Conclusion: Modified Chittick’s apparatus is a useful analytical tool for monitoring of the CO2 from effervescent granules as a function of method of preparation.