Main Article Content

Comparison between flutter valve drainage bag and underwater seal device for the management of non-massive malignant and paramalignant pleural effusions


Olugbenga Olalekan Ojo
Martins Oluwafemi Thomas
Ezekiel Ogunleye
Olugbenga Olusoji
Uvie Ufuoma Onakpoya

Abstract

Introduction: the aim of this study is to compare the use of flutter valve drainage bag system as an alternative to conventional underwater seal drainage bottle in the management of non-massive malignant/paramalignant pleural effusion.


Methods: forty-one patients with non-massive malignant and paramalignant pleural effusions were randomized into two groups. Group A (21patients) had their chest tubes connected to an underwater seal drainage bottle, while group B (20 patients) had their chest tubes connected to a flutter bag drainage device. Data obtained was analyzed with SPSS statistical package (version 16.0).


Results: breast cancer was the malignancy present at diagnosis in 24(58%) patients. Complication rates were similar, 9.5% in the underwater seal group and 10 % in the flutter bag drainage group. The mean duration to full mobilization was 35.0±20.0 hours in the flutter bag group and 52.7±18.5 hours in the underwater seal group, p-value 0.007. The mean length of hospital was 7.9±2.2 days in the flutter bag group and 9.8±2.7 days in the underwater seal group. This was statistically significant, p-value of 0.019. There was no difference in the effectiveness of drainage between both groups, complete lung re-expansion was observed in 16(80%) of the flutter bag group and 18(85.7%) of the underwater seal drainage group, p-value 0.70.


Conclusion: the flutter valve drainage bag is an effective and safe alternative to the standard underwater seal drainage bottle in the management of non-massive malignant and paramalignant pleural effusion.


Journal Identifiers