Main Article Content

Biomechanical cyclic loading test of a synthetic ligament fixation system used for intra-articular stabilization of deficient canine stifles


Bastien Goin
Philippe Buttin
Yoann Lafon
Michel Massenzio
Eric Viguier
Thibaut Cachon

Abstract

Background: Cranial cruciate ligament rupture (CCLr) is the most common cause of hind limb lameness in dogs. Currently, surgical management of  CCLr is mostly performed using tibial osteotomy techniques to modify the biomechanical conformation of the affected stifle. These surgical  techniques have a significant complication rate, associated with persistent instability of the stifle which may lead to chronic postoperative pain. Over  the last decade, studies have been published on various techniques of anatomical caudal cruciate ligament reconstruction in veterinary  practice, using physiological autografts or woven synthetic implants.


Aim: The aim of this ex vivo biomechanical study is to investigate the ex vivo dynamic biomechanical behavior of a synthetic implant ultrahigh  molecular weight polyethylene (UHMWPE) implant fixed with interference screws for the treatment of CCLr in dogs, according to a fatigue protocol  (48 hours per test).


Methods: Seven stifles from four skeletally mature canine cadavers were implanted with the synthetic implant. It was fixed with four interference  screws inserted in transversal and oblique tunnels in both the distal femur and the proximal tibia. For each case, 100,000 cycles were performed at  0.58 Hz, with traction loads ranging from 100 to 210 N.


Results: Neither screw-bone assembly rupture nor a pull-out issue was observed during the dynamic tests. Linear stiffness of the implants  associated with a fixation system with four interference screws increased over time. The final displacement did not exceed 3 mm for five of the  seven specimens. Five of the seven synthetic implants yielded to a lengthening in functional range (0–3 mm). Linear stiffness was homogeneous  among samples, showing a strong dynamic strength of the interference screw-based fixations of the UHMWPE implant in the femoral and tibial  bones.


Conclusion: This study completes the existing literature on the biomechanical evaluation of passive stifle stabilization techniques with a  testing protocol focused on cyclic loading at a given force level instead of driven by displacement. These biomechanical results should revive interest  in intra-articular reconstruction after rupture of the CCLr in dogs.


Journal Identifiers


eISSN: 2218-6050
print ISSN: 2226-4485