Main Article Content

Acute Toxicity Determination Of Pyrrolobenzothiazine And Pyrrolobenzoxazine Ring Systems On Mice


CO Okafor
MU Akpuaka

Abstract

Toxicity tests were carried out on two Bezethiazine and Benzoxazine derivatives. For this experiment, a total of sixty (60) Albino mice with average weight range 18-26g were employed. For each test compound, thirty (30) mice were distributed in five cages and fed ad libitum for 14 days for acclimatization. The test compounds were suspended in a non-toxic solvent (Tween 80) and intraperitoneally administered into the mice at doses of 450mg/kg, 500mg/kg, 550mg/kg and 600mg.kg. The results showed that the compound pyrrolobenzothiazine ring system has LD50 value of 500.00mg/kg, while the compound pyrrolobenzoxazine ring system has an LD50 value of 517.60mg/kg. These results are indicative of low toxicity values for the two compounds.


KEY WORDS: Toxicity, LD50, Mice, Benzothiazine, Benzoxazine.


J.Expt. & Clin. Anat. 2(1) 2003: 34-37

Journal Identifiers


eISSN: 1596-2393