Main Article Content

Geophysical investigation of foundation failure at Medina Estate, Lagos, Southwestern Nigeria


M.A. Oladunjoye
K.O. Adejato
A.O. Ogunkoya

Abstract

Integrated geophysical investigation involving Ground Penetrating Radar (GPR) and Electrical Resistivity methods were carried out at Medina Estate, Lagos southwestern Nigeria to map the subsurface lithology in order to delineate its peat stratigraphy that has been causing foundation failure in the area.


Twenty-one traverses (varying from 35-880 m in length) of Ground Penetrating Radar (GPR) survey were conducted along the streets of Medina trending NE-SW and NW-SE directions using the Mala 250 MHZ bi-static shielded antenna. Thirty-six Vertical Electrical Soundings (VES) were carried out using Schlumberger electrode array at some selected points along the established traverses within the area. The GPR data were processed into radar section using Rad Explorer software. The VES data were interpreted quantitatively using the partial curve matching method and 1-D forward modeling with Win Resist Software. Available litho-logs from boreholes drilled within the area were compared with the geophysical results.


Results of the GPR survey delineated three geologic layers which include the topsoil with high amplitude, parallel to sub parallel, horizontal reflections, with thickness varying from 1 to 2 m across the entire profiles and composed of lateritic clay; peat layer with low amplitude, parallel sinuous/wavy reflections with depth of occurrence ranging from 2.0 to 8 m and clay with low amplitude, planar, horizontal, sub-parallel reflections underlying the peat layer. Vertical Electrical Sounding results revealed the presence of three geological layers which are the topsoil, peat and clay and sandy clay with layer resistivity values ranging from 20- 225 Ωm, 5 – 90 Ωm and 36 to 366 Ωm and thickness values ranging from 0.5 – 2 m, 4.0-29.0 m and infinity respectively. Borehole information confirms the occurrence of shallow peat with depth ranging from 1.5 to 9 m and clay layer with depth ranging from 9 to 21 m beneath the area. The GPR survey results correlates with the well logs acquired in the study area. Based on the correlation of the geophysical results with the well logs, the GPR gives better information about the peat layer compared to the Electrical Resistivity Method.


The information obtained from this study shows that the soils at shallow depth are organic soils which are difficult foundation materials because they exhibit very high compressibility, as such making shallow foundation impossible except some form of soil improvement is carried out. The alternative approach is the adoption of deep foundations in form of piles.


Keywords: Foundation Failure, Geophysical Investigation, Ground Penetrating Radar, Vertical Electrical Sounding, Peat.


Journal Identifiers


eISSN: 2992-4502
print ISSN: 1596-6798